DINÂMICA DO ENTUPIMENTO DE GOTEJADORES EM FUNÇÃO DA APLICAÇÃO DE CARBONATO DE POTÁSSIO
DOI:
https://doi.org/10.15809/irriga.2008v13n2p288-297Abstract
DINÂMICA DO ENTUPIMENTO DE GOTEJADORES EM FUNÇÃO DA APLICAÇÃO DE CARBONATO DE POTÁSSIO
Pedro Róbinson Fernandes de Medeiros; Rubens Duarte Coelho; Allan Cunha Barros; Ralini Ferreira de Melo
Departamento de Engenharia Rural, Escola Superior de Agricultura Luiz de Queiroz, Universidade de São Paulo, Piracicaba, SP, prfmede@esalq.usp.br
1 RESUMO
O objetivo deste trabalho foi avaliar a dinâmica do entupimento de gotejadores em função da aplicação de carbonato de potássio e posterior aplicação de ácido nítrico na água de irrigação. O ensaio foi conduzido em bancada no laboratório de Hidráulica da ESALQ, utilizando 26 tipos de tubogotejadores diferentes, submetendo-os a diferentes concentrações (200, 300 e 400ppm) de carbonato de potássio via água de irrigação, com um tempo de 360h de irrigação. Os resultados mostraram que ocorreu uma significativa obstrução parcial e gradual para o modelo T1, se comparado com os outros modelos ensaiados. Os valores de vazão relativa em média obtiveram um coeficiente de variação de 7,91% no geral. E concluindo, o tratamento com ácido nítrico não foi satisfatório, devendo-se estudar uma melhor adequação do manejo deste produto.
UNITERMOS: Vazão media, obstrução química, ácido nítrico
MEDEIROS, P. R. F. de; COELHO, R. D.; BARROS, A. C.; MELO, R. F. de.
DRIPPER CLOGGING DUE TO POTASSIUM CARBONATE APPLICATION
2 ABSTRACT
The objective of this experiment was to evaluate the clogging dynamics due to potassium carbonate application after nitric acid application in water irrigation. The test was performed in benches in the Hydraulics laboratory at ESALQ-USP, using 26 different types of drip lines and three different concentrations of potassium carbonate (200, 300 and 400 ppm) in irrigation water. Irrigation time was 360 h. The results showed that a significant partial and gradual clogging in model T1 occurred when compared to other studied models. Relative flow values presented a variation coefficient of 7.91% in general, and the treatment with nitric acid was not satisfactory. New research should be carried out for this product better management.
KEY WORDS: average outflow, chemical clogging, nitric acid.
Downloads
Published
How to Cite
Issue
Section
License
This magazine provides public access to all its content, following the principle that free access to research generates greater global knowledge exchange. Such access is associated with a growing reading and citation of an author's work. The copyright of articles published in Revista Irriga is the property of the authors, with first publication rights for the journal. Because they appear in this publicly accessible magazine, articles are free to use, for their own purposes, for educational and non-commercial purposes. Further details can be obtained at http://creativecommons.org/licenses/by-nc-nd/4.0